End PlatesEnd plates are designed to allow you to install or remove your basic components without direct pipe connections to the components. In addition, each series has end plates one port size larger than the basic units, allowing you to take full advantage of the QUBE's superior performance. There are two types: Type 0731 has slots for screw pass through, and Type 0732 has tapped holes.
| Kit Number |
Port Sizes** |
Contains |
Application |
| Type 0731 |
Type 0732 |
Screws |
O-Rings |
| PK3500-** |
01(1/8"),02(1/4"),03(3/8") |
0 |
1 |
0 |
0 |
shut off |
| PK3510-** |
01(1/8"),02(1/4"),03(3/8") |
1 |
1 |
2 |
1 |
filter or lubricator |
| PK3520-** |
01(1/8"),02(1/4"),03(3/8") |
1 |
|
2 |
1 |
R,B,FRL,BL w/shut off |
| PK3530-** |
01(1/8"),02(1/4"),03(3/8") |
2 |
|
4 |
2 |
R,B,FRL,BL |
| PK5500-** |
02(1/4"),03(3/8"),04(1/2") |
0 |
1 |
0 |
0 |
shut off |
| PK5510-** |
02(1/4"),03(3/8"),04(1/2") |
1 |
1 |
2 |
1 |
filter or lubricator |
| PK5520-** |
02(1/4"),03(3/8"),04(1/2") |
1 |
|
2 |
1 |
R,B,FRL,BL w/shut off |
| PK5530-** |
02(1/4"),03(3/8"),04(1/2"),06(3/4") |
2 |
|
4 |
2 |
R,B,FRL,BL |
| PK1050-** |
02(1/4"),03(3/8"),04(1/2"),06(3/4") |
0 |
1 |
0 |
0 |
shut off |
| PK1051-** |
02(1/4"),03(3/8"),04(1/2"),06(3/4") |
1 |
1 |
2 |
1 |
filter or lubricator |
| PK1052-** |
02(1/4"),03(3/8"),04(1/2"),06(3/4") |
1 |
|
2 |
1 |
R,B,FRL,BL w/shut off |
| PK1053-** |
02(1/4"),03(3/8"),04(1/2"),06(3/4") |
2 |
|
4 |
2 |
R,B,FRL,BL |
| Series |
Plate Type |
Dimensions |
| Plate Height |
Plate Depth |
Plate Thickness |
Slot Width |
Tapped Hole Thread |
| 35 |
0731 |
1.594 |
1.594 |
0.900 |
0.172 |
N/A |
| 35 |
0732 |
1.594 |
1.594 |
0.900 |
N/A |
#8-32 UNC-2B |
| 55 |
0731 |
2.000 |
2.000 |
0.703 |
0.219 |
N/A |
| 55 |
0732 |
2.000 |
2.000 |
0.703 |
N/A |
#10-32 UNF-2B |
| 105 |
0731 |
2.688 |
2.688 |
1.000 |
0.266 |
N/A |
| 105 |
0732 |
2.688 |
2.688 |
1.000 |
N/A |
#¼-20 UNC-2B |
|
 |
Diverter BlocksDiverter blocks are designed to mount in a variety of configurations with the capability of having branch line components mounted directly, giving multiple air lines with minimal pressure drop. Use untapped blocks within components, either at beginning or end of system.
| Part Number |
Dimensions |
Application |
| Plate Thickness |
Plate Height |
Plate Depth |
Inlet Port |
Branch Port |
| DK3510-3-2 |
1.930 |
1.690 |
1.690 |
3/8" NPT |
1/4" NPT |
tapped 3/8" in & out, two 1/4" branches |
| DK7510 |
2.000 |
2.000 |
2.000 |
N/A |
1/4" NPT |
in & out not tapped, two 1/4" branches |
| DK7510-3-2 |
2.000 |
2.000 |
2.000 |
3/8" NPT |
1/4" NPT |
tapped 3/8" in & out, two 1/4" branches |
| DK7510-3-3 |
2.000 |
2.000 |
2.000 |
3/8" NPT |
3/8" NPT |
tapped 3/8" in & out, two 3/8" branch lines |
| DK1051-6-4 |
2.750 |
2.690 |
2.69 |
3/4" NPT |
1/2" NPT |
tapped 3/4" in & out, two 1/2" branch lines |
|