are available from these manufacturers: |
| Arrow Pneumatics | Cim-Tek | Hydac Technology Corp. |
| Hy-Pro Filters, Inc. | Lenz, Inc. | MP Filtri, Inc. |
| PTI Filter |
Arrow Pneumatics, Inc. |
| The Arrow Pneumatics manufactures two types of in-line hydraulic filters. These are for small, high pressure systems on the pressure side of the pump to prevent foreign particles of 25 microns and larger, such as those created by pump wear, from entering valves. | |||||||||||||||
Hydraulic In-Line FilterThis in-line filter provides protection for small, high pressure systems up to 3,000 psi. A sintered bronze element insures protection against crushing should dirt accumulate and increase pressure drop across the element. The unique construction features an anodized aluminum housing for light weight, and a conically shaped sintered bronze element positioned by a retaining spring to allow true, uninterrupted axial flow. Special viton O-rings are available for oil systems where chemical action may be a problem. The standard 25 micron bronze filter element can be easily cleaned or replaced. Nominal filtration ratings of 90, 40, or 10 microns are available. Maximum operating pressure is 3,000 psi. Operating temperatures are 35°F to 200°F. For viton O-rings, the operating temperatures are 35°F to 400°F.
Use suffix V for viton seals. For 90, 40, or 10 micron elements, use micron size as a dash number and add to part no., i.e., 9052-10, EK9052-10. |
|||||||||||||||
Hydraulic In-Line Filter - Tee TypeThis in-line filter provides protection for small, high pressure systems up to 5,000 psi. The design is similar in performance to the model 9052 and 9053 filters, with the added convenience of a cleanable element that can be removed without breaking line connections. A filter access cap simply unscrews for easy element cleaning and replacement. The anodized aluminum housing is light weight. Porting is 1/4" NPT, 3/8" NPT or 9/16"-18 SAE pipe. Special viton O-rings are available for oil systems where chemical action may be a problem. The standard 25 micron bronze filter element can be easily cleaned or replaced. Nominal filtration ratings of 90, 40, or 10 microns are available. Maximum operating pressure is 5,000 psi. Operating temperatures are 35°F to 200°F. For viton O-rings, the operating temperatures are 35°F to 400°F.
Use suffix V for viton seals. For 90, 40, or 10 micron elements, use micron size as a dash number and add to part no., i.e., 9052T-10, EK9052-10. |
|||||||||||||||
Cim-Tek |
| The Cim-Tek Division of the Central Illinois Manufacturing Company manufactures spin-on filters that are a direct replacement for many other manufacturers' filters. Cim-Tek manufactures filters with six different types of media: resin-impregnated cellulose, Cim-Glass, Microglass, HYDROSORB®, HYDROGLASS® and wire mesh. Depending on the type of hydraulic fluid being filtered, one or more of the above types of filters will provide excellent filtration. There are four classes of hydraulic fluid where Cim-Tek filters can be specified. These classes are:
Cim-Glass is constructed of high-performance microglass laminated to resin-impregnated cellulose. Microglass is a high-performance particulate filter with three times the dirt-holding capacity of the resin-impregnated cellulose filter. HYDROSORB® is a patented filter medium using a fiberglass impregnated with a super-absorbent and laminated to a resin-impregnated cellulose for particulate and water removal. HYDROGLASS® is a high-performance patented medium of HYDROSORB and microglass for water and particulate removal. Wire screen is stainless steel wire mesh. |
Spin-On Low Pressure Filter Elements |
||
20 Series Spin-On Standard Length Filter ElementsThe 20 Series Standard Length Filter with 1"-12UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
20 Series Spin-On Extended Length Filter ElementsThe 20 Series Extended Length Filter with 1"-12UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
40 Series Spin-On Standard Length Filter ElementsThe 40 Series Standard Length Filter with 1-1/2"-16UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
40 Series Spin-On Extended Length Filter ElementsThe 40 Series Extended Length Filter with 1-1/2"-16UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
21 Series Spin-On Standard Length Filter ElementsThe 21 Series Standard Length Filter with 1-1/8"-16 UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
22 Series Spin-On Standard Length Filter ElementsThe 22 Series Standard Length Filter with 1-1/4"-12 UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
22 Series Spin-On Extended Length Filter ElementsThe 22 Series Extended Length Filter with 1-1/4"-12 UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Specifications |
||
Spin-On Low Pressure Metric Filter Elements |
||
23 Series Spin-On Metric Standard Length Filter ElementsThe 23 Series Metric Standard Length Filter with British 3/4"-14 BSP threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Metric Specifications |
||
41 Series Metric Spin-On Standard Length Filter ElementsThe 41 Series Metric Standard Length Filter with British 1-1/4"-11 BSP threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Metric Specifications |
||
Spin-On Medium Pressure Filter Elements |
||
30 Series Spin-On Medium Pressure Standard Length Filter ElementsThe 30 Series Standard Length Filter with 1-1/2"-16 UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Medium Pressure Specifications |
||
30 Series Spin-On Extended Length Filter ElementsThe 30 Series Extended Length Filter with 1-1/2"-16 UNF threads is designed to remove contaminants from hydraulic systems for multiple applications. Hydraulic fluids are efficiently filtered through return line and suction line filters for:
The filters are interchangeable with the following:
Cim-Tek Medium Pressure Specifications |
||
Suction Strainer Elements |
||
Mesh Tank StrainersThe mesh tank strainers are designed for hydraulic fluid reservoirs. The strainers are constructed of 100 mesh stainless steel cloth set in die-cast aluminum endcaps sealed with epoxy adhesive. 3 psi by-pass valves are optional to detour pump starvation in the event the strainer becomes plugged with contaminates. Consult the factory for BSP threads and other configurations. Lube oils, gear oils, coolants, and synthetic fluids are compatible with the mesh tank strainers.Cim-Tek Mesh Tank Strainer Specifications |
||
Industrial Replacement Cartridges |
||
Industrial Replacement 6" x 18" CartridgesThe Industrial Replacement 6" x 18" Cartridges are standard in the industry for interchanging with:
|
||