Arrow Pneumatics, Inc.Air Dryers |
Series RH Regenerative Heatless Air DryerSeries RH is a twin tower regenerative air dryer. They are the dryers of choice when traditional refrigerated dryers do not provide sufficient air quality required for today's applications. Arrow's reliable "RH" series of heatless twin tower regenerative dryers normally produce -40°F and can optionally be as low as -100°F dew points. The dryer utilizes activated alumina for efficient drying of compressed air and will operate under extreme environmental conditions. Activated alumina is aluminum oxide that is highly porous and exhibits tremendous surface area (350 sq. meters/gram). Activated alumina is resistant to thermal shock and abrasion. It has a smooth, uniform ball size that prevents channeling of the air flow, which maintains low bed velocities. This maintains air contact time for efficient moisture removal and minimal pressure drop.Arrow's microprocessor dryer controls are housed in a NEMA 4 rated enclosure and provide control of pneumatically pilot valves chosen for long life and high air flow. |
|
![]() |
Standard Features of Heatless Regenerative Dryers:
|
|
|
| Model | In/Outlet Conn. | Flow Capacity SCFM | Height Inches | Width Inches | Depth Inches | Weight Lbs. | Prefilter Model | Afterfilter Model |
| RH203 | 3/4" NPT | 50 | 40 | 44 | 24 | 360 | F505-06DF | F329-06-3 |
| RH204 | 3/4" NPT | 50 | 40 | 44 | 24 | 508 | F505-06DF | F329-06-3 |
| RH205 | 3/4" NPT | 75 | 40 | 44 | 24 | 599 | F505-06DF | F329-06-3 |
| RH206 | 1" NPT | 100 | 64 | 44 | 24 | 627 | F508-08DF | F329-08-3 |
| RH207 | 1" NPT | 125 | 64 | 44 | 24 | 657 | F508-08DF | F329-08-3 |
| RH208 | 1-1/2" NPT | 150 | 75 | 49 | 36 | 739 | F510-12DT | F329-12-3 |
| RH209 | 1-1/2" NPT | 200 | 75 | 49 | 36 | 797 | F510-12DT | F329-12-3 |
| RH210 | 1-1/2" NPT | 250 | 75 | 49 | 36 | 855 | F510-12DT | F329-12-3 |
| RH211 | 2" NPT | 300 | 68 | 51 | 36 | 918 | F510-16DT | F3N1-16-3 |
| RH212 | 2" NPT | 350 | 68 | 51 | 36 | 1124 | F510-16DT | F3N1-16-3 |
| RH213 | 2" NPT | 400 | 86 | 51 | 36 | 1187 | F518-16DT | F3N1-16-3 |
| RH214 | 2" NPT | 500 | 86 | 51 | 36 | 1245 | F518-16DT | F3N1-16-3 |
| RH215 | 2-1/2" NPT | 650 | 97 | 67 | 36 | 1905 | F519-24DT | F3NHF-24-3 |
| RH216 | 2-1/2" NPT | 750 | 97 | 67 | 36 | 2022 | F529-24DTF | F3NHF-24-3 |
| RH217 | 2-1/2" NPT | 900 | 97 | 67 | 36 | 2197 | F529-24DT | F3NHF-246-3 |
| RH218 | 3" FLG | 1100 | 97 | 72 | 36 | 2590 | F5AX2M-24DF | F3AX2M-24-3 |
| RH219 | 3" FLG | 1300 | 97 | 72 | 36 | 3350 | F5AX2M-24DF | F3AX2M-24-3 |
| RH220 | 3" FLG | 1500 | 122 | 96 | 60 | 3775 | F5AX2L-24DF | F3AX2M-24-3 |
| RH221 | 3" FLG | 1800 | 122 | 96 | 60 | 4550 | F5AX2L-24DF | F3AX2M-24-3 |
| RH222 | 3" FLG | 2100 | 122 | 96 | 60 | 5725 | F5AX3L-32DF | F3AX2M-32-3 |
| RH223 | 4" FLG | 2500 | 122 | 108 | 60 | 6500 | F5AX4L-48DF | F3AX3L-48-3 |
| RH224 | 4" FLG | 3000 | 122 | 108 | 60 | 8500 | F5AX4L-48DF | F3AX3L-48-3 |
| 1) Dew Point Demand Plus 2) Dew Point Demand 3) High Humidity Alarm 4) -100°F Pressure Dew Point 5) Remote Alarm Contacts 6) Remote Alarm Dry Contacts 7) NEMA 7 Explosion Proof Electrical Construction 8) Low Ambient Package 9) 220V/1ph/60Hz 10) Pre-piped Filter Package 11) Three Valve Bypass Filter Package 12) Seven Valve Bypass Filter Package 13) RS-232 Serial Communications Interface 14) Total Pneumatic Controls |
| RH | 203 | A | 1 | A | 1 | A | 1 | A | 1 | A | 1 | Heatless regenerative dryer; 50 SCFM; -40°F dew point, 120v/1ph/60Hz;NEMA 4; no dew point control & monitoring options; no heater option; no remote alarm contact options; no pre-piping and bypass options, no RS-232 serial communications interface, no low ambient options; no cool down loop option. |
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ 1 2 |
Cool Down Loop Option (BP Dryers Only) None Blower Purge Cool Down Loop |
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ A B |
Low Ambient Option None Low Ambient Insulation |
|
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ 1 2 |
RS-232 Interface Option None RS-232 Serial Communications Interface |
||
| | | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
+ A B C D |
Pre-Piping and Bypass Option None Pre-piped Filter Package Pre-piped Filter Package w/3 Valve Dryer Bypass Pre-piped Filter Package w/7 Valve Dryer Bypass |
|||
| | | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
+ 1 2 3 |
Remote Alarm Contacts Option None Remote Alarm Contacts (120V) Remote Alarm Dry Contacts |
||||
| | | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
+ A B C D |
Heater Options (RE Dryers Only) None Heater Overtemp Alarm Power Saver Thermal Control Heater Overtemp Alarm and Power Saver |
|||||
| | | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
+ 1 2 3 4 5 |
Dew Point Control & Monitoring Options None Dew Point Demand Plus Dew Point Demand Dew Point Demand and High Humidity Alarm High Humidity Alarm |
||||||
| | | | | |
| | | | |
| | | | |
| | | | |
+ A B C |
Electrical Construction NEMA 4 NEMA 7 Total Pneumatic Control (RH Dryers Only) |
|||||||
| | | | | | |
| | | | | |
| | | | | |
+ 1 2 3 4 |
Voltage 120V/1ph/60Hz 480V/3ph/60Hz 220V/1ph/60Hz 220V/3ph/60Hz |
||||||||
| | | | |
| | | |
+ A B |
Dew Point -40°F -100°F |
|||||||||
| | | | | | | | | | | | | | | | | | | | | | | | |
+ 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 |
Dryer Size 35 SCFM 50 SCFM 75 SCFM 100 SCFM 125 SCFM 150 SCFM 200 SCFM 250 SCFM 300 SCFM 350 SCFM 400 SCFM 500 SCFM 650 SCFM 750 SCFM 900 SCFM 1100 SCFM 1300 SCFM 1500 SCFM 1800 SCFM 2100 SCFM 2500 SCFM 3000 SCFM |
||||||||||
| + RH |
Model Heatless Regenerative Dryer |
|||||||||||