Arrow Pneumatics, Inc.Air Dryers |
Series RE Externally Heated Regenerative Air DryerSeries RE is an externally heated twin tower regenerative air dryer. They combine the high reliability of Arrow's "RH" series desiccant dryer and add external heaters to for the "RE" series dryer. Dew points, normally -40°F, can be optionally as low as -100°F. Purge air is approximately 7% of rated flow, thus reducing the operating costs of the heated twin tower regenerative dryers compared to heatless regenerative dryers. Purge air in the "RE" series is heated by a 100% efficient incoloy sheath electric heater housed in an externally mounted shell. A thermostat controls the temperature of the heater allowing long life and energy savings. The heater and purge piping are insulated for safety and further energy savings. Arrow "RE" series heated dryers have microprocessor controls housed in a NEMA 4 rated enclosure. Pneumatically actuated valves have been chosen for long life and high air flow. |
|
![]() |
Standard Features of Externally Heated Regenerative Dryers:
|
|
|
| Model | In/Outlet Conn. | Flow Capacity SCFM | Heater Power (KW) | Height Inches | Width Inches | Depth Inches | Weight Lbs. | Prefilter Model | Afterfilter Model |
| RE231 | 3/4" NPT | 50 | .75 | 40 | 44 | 24 | 440 | F505-06DF | F329-06-3 |
| RE232 | 3/4" NPT | 50 | 1.25 | 40 | 44 | 24 | 600 | F505-06DF | F329-06-3 |
| RE233 | 1" NPT | 100 | 1.50 | 64 | 44 | 24 | 760 | F508-08DF | F329-08-3 |
| RE234 | 1-1/2" NPT | 150 | 2.00 | 75 | 49 | 36 | 930 | F510-12DT | F329-12-3 |
| RE235 | 1-1/2" NPT | 200 | 2.50 | 75 | 49 | 36 | 1050 | F510-12DT | F329-12-3 |
| RE236 | 1-1/2" NPT | 250 | 3.00 | 75 | 49 | 36 | 1330 | F510-12DT | F329-12-3 |
| RE237 | 2" NPT | 300 | 4.00 | 68 | 51 | 36 | 1525 | F510-16DT | F3N1-16-3 |
| RE238 | 2" NPT | 350 | 4.00 | 68 | 51 | 36 | 1700 | F510-16DT | F3N1-16-3 |
| RE239 | 2" NPT | 400 | 5.00 | 86 | 51 | 36 | 1940 | F518-16DT | F3N1-16-3 |
| RE240 | 2" NPT | 500 | 6.00 | 86 | 51 | 36 | 2275 | F518-16DT | F3N1-16-3 |
| RE241 | 2-1/2" NPT | 650 | 6.50 | 97 | 67 | 36 | 2650 | F519-24DT | F3NHF-24-3 |
| RE242 | 2-1/2" NPT | 750 | 7.50 | 97 | 67 | 36 | 3170 | F529-24DTF | F3NHF-24-3 |
| RE243 | 2-1/2" NPT | 900 | 9.00 | 97 | 67 | 36 | 4175 | F529-24DT | F3NHF-246-3 |
| RE244 | 3" FLG | 1100 | 12.00 | 97 | 72 | 36 | 4580 | F5AX2M-24DF | F3AX2M-24-3 |
| RE245 | 3" FLG | 1300 | 12.00 | 97 | 72 | 36 | 4580 | F5AX2M-24DF | F3AX2M-24-3 |
| RE246 | 3" FLG | 1500 | 15.00 | 122 | 96 | 60 | 5020 | F5AX2L-24DF | F3AX2M-24-3 |
| RE247 | 3" FLG | 1800 | 20.00 | 122 | 96 | 60 | 5410 | F5AX2L-24DF | F3AX2M-24-3 |
| RE248 | 4" FLG | 2100 | 20.00 | 122 | 96 | 60 | 6040 | F5AX3L-32DF | F3AX2M-32-3 |
| RE249 | 4" FLG | 2500 | 24.00 | 122 | 108 | 60 | 8720 | F5AX4L-48DF | F3AX3L-48-3 |
| RE250 | 4" FLG | 3000 | 30.00 | 122 | 108 | 60 | 9880 | F5AX4L-48DF | F3AX3L-48-3 |
| 1) Dew Point Demand Plus 2) Dew Point Demand 3) High Humidity Alarm 4) -100°F Pressure Dew Point 5) Remote Alarm Contacts 6) Remote Alarm Dry Contacts 7) NEMA 7 Explosion Proof Electrical Construction 8) Low Ambient Package 9) 220V/1ph/60Hz 10) 220V/1ph/60Hz 11) Pre-piped Filter Package 12) Three Valve Bypass Filter Package 13) Seven Valve Bypass Filter Package 14) Power Saver Thermal Control 15) Heater Overtemp Alarm 16) RS-232 Serial Communications Interface |
| RE | 231 | A | 1 | A | 1 | A | 1 | A | 1 | A | 1 | Externally heated regenerative dryer; 50 SCFM; -40°F dew point, 120v/1ph/60Hz;NEMA 4; no dew point control & monitoring options; no heater option; no remote alarm contact options; no pre-piping and bypass options, no RS-232 serial communications interface, no low ambient options; no cool down loop option. |
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ 1 2 |
Cool Down Loop Option (BP Dryers Only) None Blower Purge Cool Down Loop |
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ A B |
Low Ambient Option None Low Ambient Insulation |
|
| | | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
+ 1 2 |
RS-232 Interface Option None RS-232 Serial Communications Interface |
||
| | | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
+ A B C D |
Pre-Piping and Bypass Option None Pre-piped Filter Package Pre-piped Filter Package w/3 Valve Dryer Bypass Pre-piped Filter Package w/7 Valve Dryer Bypass |
|||
| | | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
+ 1 2 3 |
Remote Alarm Contacts Option None Remote Alarm Contacts (120V) Remote Alarm Dry Contacts |
||||
| | | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
| | | | | |
+ A B C D |
Heater Options (RE Dryers Only) None Heater Overtemp Alarm Power Saver Thermal Control Heater Overtemp Alarm and Power Saver |
|||||
| | | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
| | | | | | |
+ 1 2 3 4 5 |
Dew Point Control & Monitoring Options None Dew Point Demand Plus Dew Point Demand Dew Point Demand and High Humidity Alarm High Humidity Alarm |
||||||
| | | | | |
| | | | |
| | | | |
| | | | |
+ A B C |
Electrical Construction NEMA 4 NEMA 7 Total Pneumatic Control (RE Dryers Only) |
|||||||
| | | | | | |
| | | | | |
| | | | | |
+ 1 2 3 4 |
Voltage 120V/1ph/60Hz 480V/3ph/60Hz 220V/1ph/60Hz 220V/3ph/60Hz |
||||||||
| | | | |
| | | |
+ A B |
Dew Point -40°F -100°F |
|||||||||
| | | | | | | | | | | | | | | | | | | | | | |
+ 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 |
Dryer Size 50 SCFM 75 SCFM 100 SCFM 150 SCFM 200 SCFM 250 SCFM 300 SCFM 350 SCFM 400 SCFM 500 SCFM 650 SCFM 750 SCFM 900 SCFM 1100 SCFM 1300 SCFM 1500 SCFM 1800 SCFM 2100 SCFM 2500 SCFM 3000 SCFM |
||||||||||