[Flo-Products Company Logo]

Arrow Pneumatics, Inc.

Air Dryers

Refrigerated Air Dryer cools high temperature air from the compressor down to 35-39°F based on design conditions of 100°F inlet, 100 psig and 100°F ambient. There are three model series available: The "F" series has:
  • capacity from 10 to 100 CFM
  • Pressure dew point as low as 35°F.
  • Entire heat exchanger thermally insulated.
  • Stainless steel heat exchanger.
  • Built-in 40 micron particulate filter.
  • R-134A refrigerant.
  • Compressor thermal overload.
  • Mechanical moisture separator with automatic float type drain @99.97% efficiency.
  • Constant pressure expansion valve.
  • Refrigerant suction pressure gauge.
  • One year warranty.
The "A" series has:
  • capacity from 125 to 300 CFM
The "35xx" series has:
  • capacity from 340 to 2000 CPM
Maximum standard operating pressure ranges from 175 psig to 250 psig based on the model. Voltage ranges are 115 VAC, single phase; 208/230 VAC, single phase; 208/230 VAC, three phase; 460 VAC, three phase; and 575 VAC, three phase. In/out connections start at 3/8" O.D. and range up to 6" flange. There are numerous panel, gauge, electrical, and high pressure package options available. Some models are also available as water-cooled and as energy saving cycling dryers.
 

 
Model Flow Capacity SCFM
35°F
Dew Point
Flow Capacity SCFM
50°F
Dew Point
In/Outlet Conn. Refrig. Comp. H.P. Rating How Cooled Cooling Air Flow CFM Voltage Code Std. Instru. Panel Opt. Insrum. KW Input Drain Conn.
F-05/10 10 12 3/8" O.D. 1/6 air 125 1,2 A 15 .26 3/8" O.D.
F-10/20 20 25 1/2" FPT 1/6 air 125 1,2 A 15 .26 3/8" O.D.
F-30/40 40 50 1/2" FPT 1/4 air 125 1,2 A 15 .40 3/8" O.D.
F-50 50 62 1/2" FPT 1/4 air 185 1,2 A 15 .48 3/8" O.D.
F-70/100 100 124 1" FPT 1/2 air 350 1,2 B 15,16 .51 3/8" FPT
A-125 125 156 1" FPT 3/4 air/water 800 1,2,3 B 15,16 1.28 3/8" FPT
A-150 150 175 2" MPT 1 air/water 800 1,2,4 C 4,5,12,13 1.34 1/2" FPT
A-200 200 240 2" MPT 1 air/water 800 1,2,4 D 4,5,12,13 1.34 1/2" FPT
A-250 250 290 2" NPT 1-3/4 air/water 1125 2,3,4 D 4,5,12,13,16 2.37 1/2" FPT
A-300 300 350 2" NPT 1-3/4 air/water 1125 2,3,4 D 4,5,12,13,16 2.37 1/2" FPT
3512 340 420 3" NPT 1-3/4 air/water 2000 2,3,4 E 4,5,12,13,16 2.01 1/2" NPT
3513 375 460 3" NPT 2 air/water 2000 3,4,5 E All 2.75 1/2" NPT
3514 500 600 3" NPT 3 air/water 2100 3,4,5 E All 4.27 1/2" NPT
3515 625 750 3" NPT 3 air/water 2100 3,4,5 E All 4.27 3/4" NPT
3516 750 900 3" NPT 4 air/water 4200 3,4,5 E All 5.32 3/4" NPT
3517 1000 1250 4" FLG 5-1/2 air/water 5000 3,4,5 E All 7.15 3/4" NPT
3518 1200 1500 4" FLG 5-1/2 air/water 5000 3,4,5 E All 7.15 3/4" NPT
3519 1600 1920 4" FLG 7-1/2 air/water 5600 3,4,5 E All 8.90 3/4" NPT
3521 2000 2400 4" FLG 10* air/water 5600 3,4,5 F All 11.40 3/4" NPT
1. Flow ratings based on design conditions of 100°F inlet air temperature, 100 psi, 100°F ambient air temperature.
2. Semi-hermetic compressor, optional on 3514 and larger.
3. Water regulating valve furnished with all water cooled units.
4. KW figures for water cooled models are 15% less than figures shown. Figures include total electric draw
under maximum load, including fan motors, indicators, etc.
5. Voltage Code: VAC/Phase/Cycles
Code 1: 115/1/60 Code 2: 208-230/1/60 Code 3: 208-230/3/60 Code 4: 460/3/60 Code 5: 575/3/60.

 
Standard Instrument Panel
Description A B C D E F G H I J
On/Off Switch yes yes yes   yes yes yes yes yes yes
Power On Light yes yes yes       yes yes yes  
Compressor On Light         yes yes yes yes yes yes
Air Inlet Temperature Gauge   yes yes     yes yes yes yes yes
Air Inlet Pressure Gauge     yes yes yes yes yes yes yes yes
Air Outlet Pressure Gauge   yes       yes yes yes yes yes
Air Dew Point Temperature Gauge               yes yes  
Digital Temperature Display*       yes yes          
Differential Pressure Gauge       yes yes          
Refrigerant Suction Pressure Gauge yes yes yes yes yes yes yes yes yes yes
Refrigerant Discharge Pressure Gauge         yes yes yes yes yes  
Refrigerant Temperature Gauge           yes yes yes yes yes
Hi/Low Refrigerant Pressure Light             yes yes yes  
Low Oil Pressure Light             yes yes yes  
Cooling Water Temp. Gauges (In & Out)               yes yes  
Evaporator Pressure Guage                 yes  
NEMA 12 Enclosure             yes yes yes  
* Digital panel displays ambient air temp., compressor suction temp., compressor, discharge temp., and inlet air temp.
 
Optional Instrument and Features
1) Power On Light
2) High Inlet Air Temperature Light
3) High Refrigerant Discharge Pressure Light
 
4) Low Ambient Fan Cut-Off Switch
5) Dead System Shutdown Light
6) Condensate Drain Alarm
 
7) Air Outlet Temperature Gauge
8) Refrigerant Discharge Pressure Gauge
9) Cooling Water Temperature In/Out
 
10) Air Dew Point Temperature
11) Air Flow Gauge
12) NEMA 12 or NEMA 13 Enclosures
 
13) Waterproof Enclosure with NEMA 4 Wiring
14) Fused Disconnect Switch
15) High Pressure Package
 
16) Electronic Drain Valve w/Y-Strainer
Air Flow Variance Factors
1) As Inlet Air Temperature increases, Flow Capacity will decrease:
Inlet Air Temperature 90°F 95°F 100°F 110°F 120°F
Flow Capacity Multiplier 1.23 1.13 1.00 0.83 0.69
2) As Air Line Pressure increases, Flow Capacity will increase:
Air Line Pressure 60 psig 80 psig 100 psig 120 psig 150 psig
Flow Capacity Multiplier 0.88 0.95 1.00 1.04 1.08
3) As Ambient Air Temperature increases, Flow Capacity will decrease:
Ambient Air Temperature 80°F 90°F 100°F 110°F
Flow Capacity Multiplier 1.14 1.07 1.00 0.92
4) As Dew Point increases, Flow Capacity will increase.
If design conditions (100°F, 100 psig, 100°F ambient) remain the same, but a higher dew point is acceptable, the Flow Capacity will increase approximately in accordance with the following multipliers:
Dew Point 39°F 45°F 50°F
Flow Capacity Multiplier 1.05 1.15 1.20
These figures are simply general rules, multipliers, and formulas to help you select a dryer.

 
Arrow Filter Match
AIR COMPRESSOR ARROW FILTER MATCH
HP CFM Particulate Pre-filter Oil-Removal .9 micron Coalescing .03 micron
2 6 F354 F454W F554W
3 12 F354 F454W F554W
5 20 F386W F486W F586W
30 F386W F486W F586W
10 40 F329-08W F405-08W F505-08W
15 60 F329-08W F405-08W F505-08W
20 80 F329-08W F405-08W F505-08W
25 100 F329-08W F405-08W F505-08W
30 135 F329-08W F405-08W F505-08W
40 180 F329-12W F410-12 F510-12
50 225 F358HF-12 F410-12 F510-12
60 270 F358HF-12 F410-12 F510-12

 
If you are located in Missouri, Kansas, Nebraska, or Illinois, you may contact us at the following telephone and fax numbers with your requests or questions:
St. Louis telephone 314.428.4000 fax 314.428.4097
Kansas City telephone 913.829.5900 fax 913.829.0815
 
For ALL OTHER AREAS Please use the Info Request form for specific product information, pricing or other information. Please include company name, contact name, address, phone number and fax number to ensure a timely response.
 
Send e-mail to webmaster@flo-products.com with questions or comments about this web site.
Copyright © 2003 Flo-Products Company
Last modified:
Brochure: X1020