[Flo-Products Company Logo]

Arrow Pneumatics, Inc.

Air Dryers

Refrigerated Air Dryer

Refrigerated air dryers cool high temperature air from the compressor down to 35-39°F based on design conditions of 100°F inlet, 100 psig and 100°F ambient. The "35xx" and "40xxW" series have a capacity from 2300 to 15,000 CPM. Maximum standard operating pressure ranges from 175 psig to 200 psig based on the model. Voltage ranges are 208/230 VAC, three phase; 460 VAC, three phase; and 575 VAC, three phase. In/out connections are range from 6" to 12" flange. There are numerous panel, gauge, and electrical options available. Some models are also available with water-cooling.
 

 
Model Flow Capacity SCFM
35°F
Dew Point
Flow Capacity SCFM
50°F
Dew Point
In/Outlet Conn. Refrig. Comp. H.P. Rating Air/Water Cooled Cooling Air Flow CFM Voltage Code Std. Instru. Panel Opt. Insrum. KW Input Drain Conn.
3548W 2300 2750 6" FLG 10 no/yes N/A 3,4,5 F All 8.70 3/4" NPT
3522 2500 3000 6" FLG 10 yes/no 11600 3,4,5 G All 14.56 3/4" NPT
3523 3000 3600 6" FLG 15 yes/no 11600 3,4,5 G All 18.06 3/4" NPT
3549W 3000 3600 6" FLG 10 no/yes N/A 3,4,5 G All 13.30 3/4" NPT
3524 3750 4000 6" FLG 15 yes/no 11600 3,4,5 G All 19.57 3/4" NPT
3550W 4000 5000 6" FLG 15 no/yes N/A 3,4,5 G All 16.55 3/4" NPT
3560W 5000 5750 8" FLG 20 no/yes N/A 3,4,5 G All 16.55 3/4" NPT
4041W 5000 5750 8" FLG 25 no/yes N/A 3,4,5 H All 24.7 3/4" NPT
4042W 6250 7200 8" FLG 25 no/yes N/A 3,4,5 H All 26.3 3/4" NPT
4043W 7500 8625 8" FLG 35 no/yes N/A 3,4,5 H All 37 3/4" NPT
4044W 10000 11500 10" FLG 40 no/yes N/A 3,4,5 I All 32 3/4" NPT
4045W 12500 14375 12" FLG 50 no/yes N/A 3,4,5 I All 42 3/4" NPT
4046W 15000 17250 12" FLG 60 no/yes N/A 3,4,5 I All 57 3/4" NPT
1. Flow ratings based on design conditions of 100°F inlet air temperature, 100 psi, 100°F ambient air temperature.
2. Semi-hermetic compressor, optional on 3514 and larger.
3. Water regulating valve furnished with all water cooled units.
4. KW figures for water cooled models are 15% less than figures shown. Figures include total electric draw
under maximum load, including fan motors, indicators, etc.
5. Voltage Code: VAC/Phase/Cycles
Code 3: 208-230/3/60 Code 4: 460/3/60 Code 5: 575/3/60.
Single or Dual compressor offered or open drive.

 
Standard Instrument Panel
Description A B C D E F G H I J
On/Off Switch yes yes yes   yes yes yes yes yes yes
Power On Light yes yes yes       yes yes yes  
Compressor On Light         yes yes yes yes yes yes
Air Inlet Temperature Gauge   yes yes     yes yes yes yes yes
Air Inlet Pressure Gauge     yes yes yes yes yes yes yes yes
Air Outlet Pressure Gauge   yes       yes yes yes yes yes
Air Dew Point Temperature Gauge               yes yes  
Digital Temperature Display*       yes yes          
Differential Pressure Gauge       yes yes          
Refrigerant Suction Pressure Gauge yes yes yes yes yes yes yes yes yes yes
Refrigerant Discharge Pressure Gauge         yes yes yes yes yes  
Refrigerant Temperature Gauge           yes yes yes yes yes
Hi/Low Refrigerant Pressure Light             yes yes yes  
Low Oil Pressure Light             yes yes yes  
Cooling Water Temp. Gauges (In & Out)               yes yes  
Evaporator Pressure Guage                 yes  
NEMA 12 Enclosure             yes yes yes  
* Digital panel displays ambient air temp., compressor suction temp., compressor, discharge temp., and inlet air temp.
NOTE: Second gauge on models 4042W and 4043W is an evaporator pressure gauge when an evaporator pressure valve is used.

 
Optional Instrument and Features
1) Power On Light
2) High Inlet Air Temperature Light
3) High Refrigerant Discharge Pressure Light
 
4) Low Ambient Fan Cut-Off Switch
5) Dead System Shutdown Light
6) Condensate Drain Alarm
 
7) Air Outlet Temperature Gauge
8) Refrigerant Discharge Pressure Gauge
9) Cooling Water Temperature In/Out
 
10) Air Dew Point Temperature
11) Air Flow Gauge
12) NEMA 12 or NEMA 13 Enclosures
 
13) Waterproof Enclosure with NEMA 4 Wiring
14) Fused Disconnect Switch
15) High Pressure Package
 
16) Electronic Drain Valve w/Y-Strainer
Air Flow Variance Factors
1) As Inlet Air Temperature increases, Flow Capacity will decrease:
Inlet Air Temperature 90°F 95°F 100°F 110°F 120°F
Flow Capacity Multiplier 1.23 1.13 1.00 0.83 0.69
2) As Air Line Pressure increases, Flow Capacity will increase:
Air Line Pressure 60 psig 80 psig 100 psig 120 psig 150 psig
Flow Capacity Multiplier 0.88 0.95 1.00 1.04 1.08
3) As Ambient Air Temperature increases, Flow Capacity will decrease:
Ambient Air Temperature 80°F 90°F 100°F 110°F
Flow Capacity Multiplier 1.14 1.07 1.00 0.92
4) As Dew Point increases, Flow Capacity will increase.
If design conditions (100°F, 100 psig, 100°F ambient) remain the same, but a higher dew point is acceptable, the Flow Capacity will increase approximately in accordance with the following multipliers:
Dew Point 39°F 45°F 50°F
Flow Capacity Multiplier 1.05 1.15 1.20
These figures are simply general rules, multipliers, and formulas to help you select a dryer.

 
Arrow Filter Match
AIR COMPRESSOR ARROW FILTER MATCH
HP CFM Particulate Pre-filter Oil-Removal .9 micron Coalescing .03 micron
2 6 F354 F454W F554W
3 12 F354 F454W F554W
5 20 F386W F486W F586W
30 F386W F486W F586W
10 40 F329-08W F405-08W F505-08W
15 60 F329-08W F405-08W F505-08W
20 80 F329-08W F405-08W F505-08W
25 100 F329-08W F405-08W F505-08W
30 135 F329-08W F405-08W F505-08W
40 180 F329-12W F410-12 F510-12
50 225 F358HF-12 F410-12 F510-12
60 270 F358HF-12 F410-12 F510-12

 
If you are located in Missouri, Kansas, Nebraska, or Illinois, you may contact us at the following telephone and fax numbers with your requests or questions:
St. Louis telephone 314.428.4000 fax 314.428.4097
Kansas City telephone 913.829.5900 fax 913.829.0815
 
For ALL OTHER AREAS Please use the Info Request form for specific product information, pricing or other information. Please include company name, contact name, address, phone number and fax number to ensure a timely response.
 
Send e-mail to webmaster@flo-products.com with questions or comments about this web site.
Copyright © 2003 Flo-Products Company